Your Perfect Mist Eliminator Choice for Minimizing Entrainment
Filson is one of the best mist eliminator manufacturers in China, supplying various mist eliminator types, such as mist eliminator pad (mist pad), vane type mist eliminator, cyclone mist eliminator, fiber mist eliminator, and roof type mist eliminator. They are beneficial for various distillation columns, flue gas desulfurization, knockout drums, wet scrubbers, and evaporators.
With reliable quality and economical price, Filson mist eliminator has served hundreds of companies from all over the world and was well received. Our experienced engineering team will accompany you throughout the entire process from design and production to delivery.
Mist Eliminator
Filson mesh pad mist eliminator, also named demister pad or wire mesh mist eliminator, commonly can be tailored to your specific required sizes by metallic or plastic materials. This type excels at removing 3-5 μm size liquid droplets particularly.
Filson vane mist eliminator, also known as vane type mist eliminator or vane pack mist eliminator, can be used to remove liquid droplets and solid particles of 8-50μm. We customize various vane mist eliminator designs with hooked blades and streamlined blades.
Filson fiber mist eliminator features a unique cylindrical shape distinct from other general mist eliminator types. We can also supply the replacement of the Brink mist eliminator, with equal parameters and reliable quality.
Filson roof type mist eliminator, or roof/ridge type mist eliminator, is available in multiple designs, including plate type, X shape, etc. Various blade designs, such as hole-hook and sinusoidal blades, can be arbitrarily combined to promote droplet separation.
Filson chevron mist eliminator, or called chevron type mist eliminator, owns baffle or zigzag blade modules to meet different accuracy and flow capacity requirements. Both vertical and horizontal styles can be installed for specific flow directions.
Filson cyclone mist eliminator features a minimal diameter and weight design to handle maximal gas capacity by high centrifugal force. It is more suitable for elevated pressure conditions than mesh pads and vane-type mist eliminators.
Filson mist eliminator HVAC is an efficient solution for HVAC systems to remove mist entrainment from air intakes. It can easily avoid the adverse effects on indoor air quality and dramatically reduce below-deck corrosion.
Filson mist eliminator for wet scrubber can be designed to mesh pad type, vane type, and cyclone type to separate liquid entrainment and gases. It will assist your wet scrubber to clear exhaust gas with high efficiency.
Filson PP mist eliminator is totally made of quality polypropylene material and has mesh and vane two-type designs. Support grids can be added or not upon your request.
Filson PVC mist eliminator offers round, ring, rectangular, etc. common shapes, and other unique shapes for installation space in different sizes. With high corrosion resistance and good oxidation resistance.
Filson PE mist eliminator may be your perfect choice when you need a lightweight mist eliminator with stable chemical compatibility. It is non-toxic thus suiting food-related industries.
Filson replacement mist eliminator relies on precise cross-referenced data and years of manufacturing experience, achieving superb separation performance with low operating costs. Filson supplies the replacement of Munters mist eliminator, Amacs mist eliminator, Koch mist eliminator, Kimre mist eliminator …
Why Choose Filson Mist Eliminator?
Production: We have advanced manufacturing equipment like laser cutting machines and skilled workers with 5 years of experience. This ensures perfect fulfillment for each independent project.
Service: The fastest response is provided. Whether you need detailed product information or professional technical support, we will respond to you within 30 minutes during business hours.
Delivery: We offer immediate delivery for standard types and within 10-20 days for customized types. It may take more time for large quantities, but no more than 40 working days.
Transport: We work with major logistic companies, including FedEx, DHL, UPS, etc. Whether you require train, air freight, or sea transportation, we guarantee the fastest and safest processes.
Filson: Mist Eliminator Manufacturing Expert Serving the World
Filson mist eliminator is generally made of Stainless Steel, Duplext Stainless Steel, Titanium, Hastelloy, Inconel 625, Monel 400, PP(polypropylene), PE(polyethylene), PVC(polyvinyl chloride), FRP(fiberglass reinforced plastic) materials with high corrosion and abrasive resistance. Filson engineers are ready to help you with your most appropriate mist eliminator selection.
Filson mist eliminator particularly acts on the liquid droplets and entrained particles in sizes of 0.1 to over 50 microns. There are four optional types of mist eliminators from Filson for your specific removal entrainment sizes, including mesh, vane, cyclone, and fiber bed types.

If there is only liquid entrainment or mist with less than 10 microns in the gas, Filson mesh demister pads are your perfect choice; but if also solid particles and 8-50 micron entrainment in the gas, please pick Filson vane type or cyclone mist eliminator. Plus, the Filson fiber bed mist eliminator can handle even 0.1-micron droplets.
Mist Eliminator Type Removed Droplet Size(μm)
- Mesh Pad 3-10
- Vane type 8-50
- Cyclone type 7-20
- Fiber Bed Candle Filter 0.1-5
Filson mist eliminator can be an essential internal of desulphurization towers, absorption towers, distillation towers, and scrubbing towers to minimize liquid entrainment. Commonly employed at the top of a packed column or in conjunction with a collecting tray between two packed beds.

Or Filson mist eliminator can be installed in some systems to converge mist into larger droplets and discharge. It plays an important role in a variety of machine coolant mist, chromic acid mist, sulfuric acid mist, and oil mist removal, to ensure that air emissions achieve environmentally acceptable levels.
For mesh pad and vane type mist eliminator, Filson designs both integrated and segmented two styles to meet different application sizes. Among them, the integrated style Filson mist eliminator is more suitable for relatively smaller towers, while the segmented style is easier to transport and install for larger industrial systems.
By the way, do not worry about installation problems. There is an English manual coming with your mist eliminator to guide you, and our engineers will also assist you throughout the installation process.

Filson mist eliminator provides the vertical and horizontal configurations to fit the different directions of gas flow. Vertical type allows a higher flow rate and is easy to avoid secondary entrainment, but requires a larger footprint. While the horizontal type requires a smaller footprint and is easy to install, it is available at a lower flow rate and is prone to secondary entrainment.
In addition, after a period of use, you are recommended to clean your Filson mist eliminator to reduce scaling and restore the optimum filtration efficiency. Design a backwashing unit in your system for regular cleaning, dismantle it and spray it with clean water, or soak it in the cleaning solution.
Not only standard mist eliminator supply, but Filson’s bespoke mist eliminators can also satisfy you with the desired size, material, and shape. Just send us your specific application, required efficiency, droplet size, face velocity, or the drawing of the existing demister.
Besides, if you are searching for a quality mist eliminator with an economical mist eliminator price for your existing system, choose Filson. We design and manufacture mist eliminator replacements for almost all popular brands on the market, such as Emacs mist eliminator, Munter’s mist eliminator, Koch mist eliminator, and Krime mist eliminator.
Each mist eliminator manufactured by Filson is strictly performance tested before leaving the factory and will be wrapped in plastic film and placed in a customized wooden case. Or a pallet inside to reduce pressure during loading.
If there is any doubt about mist eliminator material, mist eliminator pressure drop, or mist eliminator design calculation, please feel free to contact Filson. Our mist eliminator specialists are 24/7 here to help you solve problems.
More information? Just a phone call or an email!
Phone: +86-157 3695 8886
Email: sales@filsonfilters.com
Looking forward to sincere cooperation with you TODAY!
What is Mist Eliminator

A mist eliminator is basically a device that separates liquids from gases. There are different types, like mesh pad, vane, cyclone, candle, and roof styles, each designed for different sizes of mist or droplets. They’re made from materials like stainless steel (SS304, SS316), titanium, and more.
These eliminators do a great job of getting rid of liquid droplets and solid particles from gases or vapor. You’ll often find them inside towers, like scrubbing towers, desulfurization towers, absorption towers, or distillation towers, as part of the liquid-gas separation process.
Mist Eliminator Function

- Reduce loss of valuable chemicals like glycol, amine, or solvent in absorption towers
- The updated throughput capacity of existing systems without costly replacement
- Protect downstream equipment like a turbine, blower, and compressor blades
- Improve purity of products by preventing side draw contamination in distillation columns
- Minimize air pollution by diminishing mist emissions to an environmentally acceptable level
How to Choose Materials for Your Mist Eliminator
Mist eliminators come in different materials, each suited for specific working conditions. If you’re unsure which material to choose, check out the table below for guidance:

Note: The above data reflects the typical conditions for standard-designed mist eliminators. Actual performance may vary depending on factors like wire diameter, vane thickness, and other design parameters.
Mist Eliminator Working Principle
The main working principles of a mist eliminator are collision, adherence, coalescence, and drainage. When mist-laden gas passes through the eliminator at a certain speed, the mist droplets collide with the wires (or blades), stick to them, and merge into larger droplets. These larger droplets then drain away, effectively separating the liquid from the gas.

Using multi-layer mesh wires or multi-fold plate designs enhances the chances of capturing mist, as any mist that isn’t removed initially gets caught at the next turning point. The mist removal efficiency improves as the flow rate increases—higher flow rates mean greater mist inertia, which makes it easier to separate the liquid from the gas.
When the gas flow rate increases, it makes the system more resistant and uses up more energy. If the flow rate goes beyond a certain point, secondary entrainment happens, which lowers the efficiency of mist removal.
How to Calculate the Appropriate Flow Velocity of Mist Eliminator
We use the Souners-Brown equation to determine the optimal flow velocity for a specific system. For instance,

let’s consider an air-water system under standard conditions. The liquid density (PL) is 800 kg/m³, the gas density (PG) is 2 kg/m³, and the capacity factor (K) for an efficient wire mesh mist eliminator is 0.12 m/s. Using the Souners-Brown equation, we can conclude:

This value can vary depending on the type and design of the mist eliminator, the relative geometry of the demister to the steam flow, and process factors such as operating pressure, fluid viscosity, and liquid surface tension. Therefore, each condition should be analyzed individually.
How to Test FILSON Mist Eliminator
Moreover, thorough testing is crucial to ensure the reliable performance of our mist eliminators. We conduct material tests and performance tests (separation efficiency, pressure drop, and droplet size limitations) for each unit. For example, in the case of the vane-type mist eliminator test:
1. Material Testing

Every component of our mist eliminators undergoes a material inspection to ensure that the materials are fully compliant with your specifications. This guarantees that they meet your exact requirements.
2. Performance Testing
We mainly test three key properties of the mist eliminator: its separation efficiency, pressure drop, and droplet size limits. First, we install a scaled-down vane mist eliminator into the test equipment (as shown in the figure below).

a. Droplet removal efficiency testing
Then, we fill the test tower’s pool with water until the level meter reads 400mm. Next, we adjust the flow meter to 70L/h and let the system run for five minutes until it stabilizes. Once stable, we start the record. During testing, the operator adjusts the gas velocity to get more accurate data.

Afterward, we calculate the separation efficiency using the formula: Droplet Removal Efficiency =( Water in the Airflow – Droplet Intercept )/ Water in the Airflow * 100%. Two results can be obtained:
- (70-1.78)/70*100%=97.5%
- (70-1.92)/70*100%=97.3%.
We take the average of these two values as the final droplet removal efficiency: 97.4%. (Note: our customer required the removal efficiency of this vane mist eliminator to be 96%.)
b. Pressure drop testing
After testing the efficiency, we place high-precision pressure sensors at the inlet and outlet of the vane mist eliminator. Then, we slowly increase the gas flow velocity from low to high, covering the equipment’s intended operating range. At each flow speed, we measure and record the pressure drop (∆P) like this:

c. Limited droplet size testing
For testing the limited droplet size, the operator adjusts the droplet generator to produce ultra-fine droplets (e.g., 1-10μm). Then, they measure the concentration of these tiny droplets at both the inlet and outlet of the mist eliminator. The droplet size at which the capture efficiency falls below 50% is identified and defined as the limited droplet size.

FILSON Mist Eliminator Specification
- Raw Material: SS 304/304L, 316/316L, duplex stainless steel, Titanium, Nickel, Monel 400, Inconel 625, Hastelloy, PP, PE, PVC, PTFE(Teflon/F4), FRP(fiberglass reinforced plastic)
- Design Gas Velocity: 3.5-5.5 m/s
- Mist Removal Efficiency: 95-99.9 %
- Type: mesh pad, vane type, cyclone type, fiber candle filter
- Droplet Size: 0.1-50 micron
- Operating Temperature: upon the material
- Pressure Drop: less than 120 Pa
FILSON Mist Eliminator Application
- Flue Gas Desulfurization
- Refineries
- Petrochemical Plants
- Gas Absorption Systems
- Sulfuric Acid Plants
- Knockout Drums
- Evaporators
- Steam Drums
- Distillation Towers
- Wet Scrubbers


























